Catalog NewsArticlesDealersDeliveryServiceJobPartnership
Enerpred

Electric pump with explosion-proof motor and manual valve

VNER series pumps are similar to NER pumps, although being equipped with explosion-proof engine. They are supplied without electrical connection equipment.

Key characteristics:
Series: VNER...I...
Tank volume: 10-100 l
Pressure: 700 bar
Models
Accessories
Model with your options
Drawing
Additional options
Important information
Important information
Output flow rate , l/min
Model Output
flow
rate
l/min
Tank
volume
l
Motor
voltage
V, 50 Hz
Motor
size
kW
Dimensions
(BxLxH)
mm
Weightkg
VNER-1,6I10T1 1,6 10 380 2,2 420×300×530 56 priceRequest
VNER-1,6I20T1 1,6 20 380 2,2 420×300×610 58 priceRequest
VNER-1,6I40T1 1,6 40 380 2,2 560×390×660 64 priceRequest
VNER-1,6I63T1 1,6 63 380 2,2 560×390×800 65 priceRequest
VNER-2,8I20T1 2,8 20 380 3 420×300×620 75 priceRequest
VNER-2,8I40T1 2,8 40 380 3 560×390×707 81 priceRequest
VNER-2,8I63T1 2,8 63 380 3 560×390×847 84 priceRequest
VNER-5,0I40T1 5 40 380 7,5 560×390×730 143 priceRequest
VNER-5,0I63T1 5 63 380 7,5 560×390×870 145 priceRequest
VNER-5,0I100T1 5 100 380 7,5 680×620×920 150 priceRequest
VNER-10,0I100T1 10 100 380 11 680×620×920 160 priceRequest
Tank volume , l
Model Output
flow
rate
l/min
Tank
volume
l
Motor
voltage
V, 50 Hz
Motor
size
kW
Dimensions
(BxLxH)
mm
Weightkg
VNER-1,6I10T1 1,6 10 380 2,2 420×300×530 56 priceRequest
VNER-1,6I20T1 1,6 20 380 2,2 420×300×610 58 priceRequest
VNER-1,6I40T1 1,6 40 380 2,2 560×390×660 64 priceRequest
VNER-1,6I63T1 1,6 63 380 2,2 560×390×800 65 priceRequest
VNER-2,8I20T1 2,8 20 380 3 420×300×620 75 priceRequest
VNER-2,8I40T1 2,8 40 380 3 560×390×707 81 priceRequest
VNER-2,8I63T1 2,8 63 380 3 560×390×847 84 priceRequest
VNER-5,0I40T1 5 40 380 7,5 560×390×730 143 priceRequest
VNER-5,0I63T1 5 63 380 7,5 560×390×870 145 priceRequest
VNER-5,0I100T1 5 100 380 7,5 680×620×920 150 priceRequest
VNER-10,0I100T1 10 100 380 11 680×620×920 160 priceRequest
Model Output
flow
rate
l/min
Tank
volume
l
Motor
voltage
V, 50 Hz
Motor
size
kW
Dimensions
(BxLxH)
mm
Weightkg
VNER-1,6I10T1 1,6 10 380 2,2 420×300×530 56
VNER-1,6I20T1 1,6 20 380 2,2 420×300×610 58
VNER-1,6I40T1 1,6 40 380 2,2 560×390×660 64
VNER-1,6I63T1 1,6 63 380 2,2 560×390×800 65
VNER-2,8I20T1 2,8 20 380 3 420×300×620 75
VNER-2,8I40T1 2,8 40 380 3 560×390×707 81
VNER-2,8I63T1 2,8 63 380 3 560×390×847 84
VNER-5,0I40T1 5 40 380 7,5 560×390×730 143
VNER-5,0I63T1 5 63 380 7,5 560×390×870 145
VNER-5,0I100T1 5 100 380 7,5 680×620×920 150
VNER-10,0I100T1 10 100 380 11 680×620×920 160
Output
flow
rate
l/min
Tank
volume
l
Motor
voltage
V, 50 Hz
Motor
size
kW
1,6 10 380 2,2
1,6 20 380 2,2
1,6 40 380 2,2
1,6 63 380 2,2
2,8 20 380 3
2,8 40 380 3
2,8 63 380 3
5 40 380 7,5
5 63 380 7,5
5 100 380 7,5
10 100 380 11
Dimensions
(BxLxH)
mm
Weightkg
420×300×530 56
420×300×610 58
560×390×660 64
560×390×800 65
420×300×620 75
560×390×707 81
560×390×847 84
560×390×730 143
560×390×870 145
680×620×920 150
680×620×920 160
Model VNER-1,6I10T1 Output
flow
rate
l/min
1,6 Tank
volume
l
10 Motor
voltage
V, 50 Hz
380 Motor
size
kW
2,2 Dimensions
(BxLxH)
mm
420×300×530 Weightkg 56
Model VNER-1,6I20T1 Output
flow
rate
l/min
1,6 Tank
volume
l
20 Motor
voltage
V, 50 Hz
380 Motor
size
kW
2,2 Dimensions
(BxLxH)
mm
420×300×610 Weightkg 58
Model VNER-1,6I40T1 Output
flow
rate
l/min
1,6 Tank
volume
l
40 Motor
voltage
V, 50 Hz
380 Motor
size
kW
2,2 Dimensions
(BxLxH)
mm
560×390×660 Weightkg 64
Model VNER-1,6I63T1 Output
flow
rate
l/min
1,6 Tank
volume
l
63 Motor
voltage
V, 50 Hz
380 Motor
size
kW
2,2 Dimensions
(BxLxH)
mm
560×390×800 Weightkg 65
Model VNER-2,8I20T1 Output
flow
rate
l/min
2,8 Tank
volume
l
20 Motor
voltage
V, 50 Hz
380 Motor
size
kW
3 Dimensions
(BxLxH)
mm
420×300×620 Weightkg 75
Model VNER-2,8I40T1 Output
flow
rate
l/min
2,8 Tank
volume
l
40 Motor
voltage
V, 50 Hz
380 Motor
size
kW
3 Dimensions
(BxLxH)
mm
560×390×707 Weightkg 81
Model VNER-2,8I63T1 Output
flow
rate
l/min
2,8 Tank
volume
l
63 Motor
voltage
V, 50 Hz
380 Motor
size
kW
3 Dimensions
(BxLxH)
mm
560×390×847 Weightkg 84
Model VNER-5,0I40T1 Output
flow
rate
l/min
5 Tank
volume
l
40 Motor
voltage
V, 50 Hz
380 Motor
size
kW
7,5 Dimensions
(BxLxH)
mm
560×390×730 Weightkg 143
Model VNER-5,0I63T1 Output
flow
rate
l/min
5 Tank
volume
l
63 Motor
voltage
V, 50 Hz
380 Motor
size
kW
7,5 Dimensions
(BxLxH)
mm
560×390×870 Weightkg 145
Model VNER-5,0I100T1 Output
flow
rate
l/min
5 Tank
volume
l
100 Motor
voltage
V, 50 Hz
380 Motor
size
kW
7,5 Dimensions
(BxLxH)
mm
680×620×920 Weightkg 150
Model VNER-10,0I100T1 Output
flow
rate
l/min
10 Tank
volume
l
100 Motor
voltage
V, 50 Hz
380 Motor
size
kW
11 Dimensions
(BxLxH)
mm
680×620×920 Weightkg 160

The engine must be connected to the explosion-proof engine starter on the working site in accordance with safety rules and regulations of the electrical code.
Basic models are equipped with vibration-proof gauge, safety valve, pressure regulator. The hydraulic equipment is controlled by the “I” series three-position manual distribution valve (model “GR-ЗIR-1”) allowing for working stroke/pressure holding/idle stroke phases (lift cylinders, hydraulic cylinders, pipe benders, etc.) Could be used with any type of hydraulic equipment and tools, both single-acting and double-acting. Additional equipment could be installed, like a thermometer, wheels for transportation, folding handles for carrying by 2 to 4 staff members (available for stations with tanks of 40, 63, and 100 liters).

Since the station series VNER are supplied without remote and automatic control electrical equipment, it is highly recommended to connect a hydraulic tool with built-in valve to VNER pump.

Additional options for explosion-proof stations

1- Ekv Control cabinets

Control cabinets and explosion-proof alarms of ShUS type are designed to control, distribute, and commute electrical energy in the circuits of different purposes, alarm about parameters and operation modes of these circuits and their protection in explosion-hazardous areas of enterprises of coal, chemical, oil-refining, gas, and other sectors of industry where, under the operation conditions, there is a possibility of generation of explosion-hazardous mixtures of gases and vapors with air of I, IIA, IIB, IIC categories and T1-T5 groups.

2- Puv Control stations

The stations are designed for remote control over electric motor starting and control over electrical hydraulic distributor magnets.

The stations are designed for operation: with 2ExdIICT6 explosion proof mark – in explosion-hazardous areas of productions, transport means, and storage of products of chemical, oil-refining, gas and other sectors of industry.

3- Shv Cable plug/socket

Explosion-proof connectors are designed for quick connection and disconnection of cabling sections, hydraulic stations with power sources in the ground stationary and mobile electric installations with voltage up to 440 V DC and AC frequency up to 60 Hz.

Double-acting load-lifting cylinders

Aluminium load-lifting cylinders

Aluminium lock-nut load-lifting cylinders

Hydraulic cylinders with eyelets

Specify the appropriate parameters
Comment to the order
Сontact details
1 - Ekv

Control
cabinets

Built-in control and alarm systems, explosion-proof type SHUS intended to control the distribution and kommutatsiielektricheskoy energy networks for different purposes, signaling parameters and modes of operation of these networks, as well as their protection in hazardous areas of the coal, chemical, oil, gas and other industries, which, according to the operating conditions, formation of explosive mixtures of gases and vapors with air graded in classes I, IIA, IIB, IIC and groups T1-T5.

2 - Puv

Control

points

The posts are intended for remote starting the motor, electric control valve control magnets.
The posts are intended for operation: with Ex 2ExedIIST6 - in hazardous areas of production, transportation and storage of chemical, oil, gas and other industries.

3 - Shv

Male / female cable

Explosion-proof connectors are designed for quick articulation and dismemberment cable network segments, hydraulic stations with power sources in terrestrial stationary and mobile electrical installations with voltage up to 440 V DC and AC frequency to 60 Hz.

The content of this publication is subject to copyright of JSC TD ENERPRED and cannot be reproduced (even in part) without appropriate permission. JSC TD "ENERPRED" reserves the right to make any changes to the design and characteristics of the tool offered in this catalog without prior notice. Instrument specifications, including weight, dimensions and other parameters, may vary slightly.

Important information

We successfully cooperate

We have much to be proud of, because of our
partners leading companies in Russia and Eastern Europe:

Order a call

Our contacts

Irkutsk

address

Rosa Luxemburg street, 184,post office box 129
Irkutsk, 664040, Russia

Phone

+7 (3952) 211-140

Fax

+7 (3952) 555-159

Email for orders

zakaz@enerpred.com

Email

info@enerpred.com

Contact with manager

Select your region

priceRequest